Fault Code list ordered by Control Module
  • 1002 - Engine Coolant Temperature Sender - Over Temperature >110° C
  • 1004 - Hydraulic Filter Restriction Switch - Hydraulic Filter Restricted
  • 1009 - Hydraulic Oil Temperature Sender - Over Temperature >210° F
  • 1014 - Cluster Battery Monitor: Over Voltage > 16.5 volts
  • 1015 - Cluster Battery Monitor: Under Voltage < 11.5 volts
  • 1025 - Throttle Sensor - Out Of Range Short to Power
  • 1030 - Throttle Sensor - Out Of Range Short to Ground/ Open Circuit
  • 1041 - RPM Monitoring - Over Speed
  • 1045 - Fuel Level Sensor Open Circuit
  • 111 - EGR potentiometer valve could not be completely opened
  • 112 - EGR potentiometer valve could not be completely closed
  • 119 - Engine crank signal present for 300 seconds
  • 1201 - Hydraulic Filter Restriction Switch - OC
  • 1202 - RPM Monitoring - Over Speed (Max)
  • 1203 - RPM Monitoring - Open Circuit/ Short to Ground/ Short to Power
  • 1204 - Start Sequence - Key Switch State - Engine Running Plausability Fault
  • 1205 - Hydraulic Enable (EH Machines) - Hydraulic Enable Output, Short to Power
  • 1206 - CAN Connection: Configuration Response Timeout
  • 1207 - Memory Parameters - Invalid Configuration Between IC and UCM
  • 1208 - Seat Switch - Plausibility Fault
  • 1211 - Calibration Functions - Joystick Calibration Not Complete
  • 1212 - Calibration Functions - Ground Drive Calibration Not Complete
  • 1213 - Calibration Functions - Loader Valve Calibration Not Complete
  • 1214 - Calibration Functions - Throttle Calibration Not Complete
  • 1221 - Health Monitor Functions - UCM - UCM Temperature / Current Draw Over Limit
  • 1222 - Health Monitor Functions - UCM - UCM Sustained Over Temperature Limit
  • 1223 - Health Monitor Functions - UCM - UCM Sustained Over Current Limit
  • 1224 - Health Monitor Functions - UCM - Internal Memory or Core Monitoring Fault
  • 1225 - Health Monitor Functions - UCM - EEPROM Memory Checksum Fault
  • 126 - Battery voltage fault
  • 131 - Coolant temperature sensor fault
  • 134 - Intake air pressure sensor fault
  • 1350 - Hyd Enable Switch - Implausible State (Hardwire vs CAN)
  • 141 - Engine speed sensor fault
  • 1511 - Right Brake Lights Open Circuit
  • 1512 - Right Brake Lights Short to Ground
  • 1513 - Right Brake Lights Short to Power
  • 1521 - Left Brake Lights Open Circuit
  • 1522 - Left Brake Lights Short to Ground
  • 1523 - Left Brake Lights Short to Power
  • 1532 - Backup Alarm - Short to Ground
  • 1533 - Backup Alarm - Short to Power
  • 186 - EGR valve position sensor fault
  • 189 - EGR valve position driver fault
  • 1900 - UCM - UCM Ground Fault
  • 1901 - UCM - UCM Supply Voltage High
  • 1902 - UCM - UCM Supply Voltage Low
  • 1903 - UCM - UCM Supply Voltage Below Operational Limit
  • 1904 - UCM - Rail 12VB: 5V Regulators Supply Input Power Off
  • 1905 - UCM - 5VREF1 Sensor Supply Voltage Out of Range
  • 1906 - UCM - 5VREF3 Sensor Supply Voltage Out of Range
  • 1907 - UCM - Rail 12VF1: Aux Retract Input Power Off
  • 1908 - UCM - Rail 12VF2: Bucket Extend Input Power Off
  • 1909 - UCM - Rail 12VF3: Boom Raise/Lower Input Power Off
  • 1910 - UCM - Rail 12VH: Ldr Plt Interlk & Port Lock Input Power Off
  • 1911 - UCM - Rail 12VH1: Left & Right Pump Reverse Input Power Off
  • 1912 - UCM - Rail 12VM: Left & Right Brake Lights & Aux Extend Input Power Off
  • 1913 - UCM - Rail 12VS1: Bucket Curl Input Power Off
  • 1914 - UCM - Rail 12VS2: Backup Alarm Input Power Off
  • 1915 - UCM - Rail 12VT1: Two Speed Input Power Off
  • 1916 - UCM - Rail 12VU1: Right & Left Pumps Forward Input Power Off
  • 1917 - UCM - Rail 12VU2: Park Brake Solenoid Input Power Off
  • 1E5 - Sensor voltage supply fault
  • 2E5 - Sensor ground fault
  • 3000 - Engine Malfunction - ECU Fault - General/Undefined/Air Filter Restriction
  • 3007 - Engine Coolant Temperature Sender - Short to Ground
  • 3008 - Engine Coolant Temperature Sender - Open Circuit
  • 3027 - Oil pressure signal not plausible
  • 3028 - Engine Oil Pressure Switch - Engine Oil Pressure Low
  • 3029 - Engine Oil Pressure Switch - Engine Oil Pressure Switch OC
  • 3154 - Engine Preheat - Glow Plug - STP
  • 3156 - Engine Preheat - Glow Plug - OC
  • 3401 - Engine Start - Fuel Solenoid - STP
  • 3402 - Engine Start - Fuel Solenoid - OC
  • 3403 - Starter: Starter is cranked > 30s
  • 3404 - Starter - STP
  • 3405 - Starter - STG / OC
  • 3405 - ECU Power stages: Open load temperature error on the Turbocharger PWM output power stage
  • 3406 - ECU Power stages: Over temperature error on the Turbocharger PWM output power stage
  • 3408 - Lambda sensor: Oxygen concentration implausibly high
  • 3409 - Oil pressure too low
  • 3410 - Permanent governor deviation for valve
  • 3411 - Permanent governor deviation for valve
  • 3414 - Short circuit in cylinder 1 glow plug
  • 3415 - Short circuit in cylinder 2 glow plug
  • 3416 - Short circuit in cylinder 3 glow plug
  • 3417 - Short circuit in cylinder 4 glow plug
  • 3418 - ECU Power stages: SCB error on the Turbocharger PWM output power stage
  • 3419 - ECU Power stages: SCG error on the Turbocharger PWM output power stage
  • 3425 - Turbocharger: Over boost deviation at P2 too high in pressure charger regulator
  • 3426 - Low efficiency in DPF filter
  • 3427 - Diesel particulate filter (DPF): Signal range check flow resistance of the particulate filter - low
  • 3428 - Diesel Particulate Filter Pressure sensor: not plausibility error
  • 3429 - Diesel Particulate filter Pressure sensor: hoseline plausibility error
  • 3648 - EVGT Boost pressure monitoring for over boost
  • 3657 - Timeout Error of CAN-Receive-Frame CM1BC
  • 3659 - Battery voltage: Power stage diagnosis could be disabled due to high battery voltage
  • 3660 - Battery voltage: Power stage diagnosis could be disabled due to low Battery voltage
  • 3663 - EGR command saturation over higher threshold
  • 3664 - EGR command saturation over lower threshold
  • 3665 - Permanent governor deviation for valve
  • 3666 - Permanent governor deviation for valve
  • 3667 - Open load error for power stage
  • 3668 - Over temperature error for H-bridge
  • 3669 - Short circuit to battery on Out1 error for H-bridge
  • 3670 - Short circuit to battery on Out2 error for H-bridge
  • 3671 - Short circuit to ground on Out1 error for H-bridge
  • 3672 - Short circuit to ground on Out2 error for H-bridge
  • 3673 - Short circuit over load error for H-bridge
  • 3674 - Under voltage error for H-bridge
  • 3675 - DFC for long time valve drift at closed position
  • 3676 - DFC for valve position sensor voltage SRC high
  • 3677 - DFC for valve position sensor voltage SRC low
  • 3689 - Faulty diagnostic data transmission or protocol error
  • 3691 - No load error for low voltage system
  • 3692 - Over temperature error on ECU power stage for glow plug low voltage system
  • 3693 - Short circuit to battery error for low voltage system
  • 3694 - Short circuit to ground error for low voltage system
  • 3695 - Failure in glow plug cylinder 1
  • 3696 - Failure in glow plug cylinder 2
  • 3697 - Failure in glow plug cylinder 3
  • 3698 - Failure in glow plug cylinder 4
  • 3702 - Injection control: Detection of failed engine start
  • 3703 - Injection control: check of minimum rail pressure
  • 3704-3706 - Injector adjustment programming: check of missing injector adjustment value programming
  • 3707 - Lambda sensor: Open circuit at the lambda sensor Nernst cell pin
  • 3708 - Lambda sensor: Open circuit at the lambda sensor pump current pin
  • 3709 - Lambda sensor: Open circuit at the lambda sensor virtual ground pin
  • 3710 - Lambda sensor: Fault to indicate dynamics of the sensor signal too small
  • 3711 - SCB error of the LSU Heater Power stage
  • 3712 - Lambda sensor: SCG error of the LSU heater power stage
  • 3713 - Lambda sensor: Open Load error of the LSU Heater Power stage
  • 3714 - Lambda sensor: Fault code to indicate SRC High error for O2 calibration
  • 3715 - Lambda sensor: SRC Low error for O2 calibration
  • 3716 - Lambda sensor: O2 value above the max threshold
  • 3720 - Lambda sensor: Low battery voltage at the SPI chip
  • 3721 - Lambda sensor: Fault check to indicate SPI chip error of lambda sensor
  • 3722 - Lambda sensor: LSU sensor temperature Ri exceeds the maximum limit
  • 3723 - Lambda sensor: LSU sensor temperature Ri is below the minimum limit
  • 3724 - Lambda sensor: Short to battery at IA, IP, UN, VG
  • 3725 - Lambda sensor: Short to ground at IA, IP, UN, VG
  • 3736 - O2 concentration is outside the predefined window during Heater coupling detection
  • 3737 - Lambda sensor: Over temperature error of the LSU Heater Power stage
  • 3766 - Diesel particulate filter pressure sensor: Fault check for the pressure sensor plausibility
  • 3771 - Oxidation Catalyst: Up and down stream temperature sensors in Oxidation catalysts exchanged
  • 3773 - EVGT Turbocharger Control Underboost Pressure failure
  • 3786 - Diesel particulate filter signal range check is high
  • 3787 - Diesel particulate filter (DPF) : Signal range check flow resistance of the particulate filter - very high
  • 3789 - Regeneration duration exceeds maximum allowed duration
  • 3790 - Diesel particulate filter: Signal range check flow resistance of the particulate filter - max
  • 3794 - Intake air pressure sensor: Plausibility check for air pressure at the upstream of intake valve sensor
  • 3795 - Intake air pressure sensor: Plausibility check for air pressure at the upstream of intake valve sensor
  • 3796 - Diesel particulate filter pressure sensor hose line error
  • 3798 - Diesel particulate filter pressure sensor: SRC low for differential pressure sensor
  • 3799 - Pressure Relief valve: pressure relief valve is forced to open, perform pressure shock
  • 3800 - Pressure relief valve: Quantity balance check if a successful PRV opening is ensured
  • 3801 - Turbine upstream pressure sensor: SRC high for turbine upstream pressure sensor
  • 3802 - Turbine upstream pressure sensor: SRC low for turbine upstream pressure sensor
  • 3815 - Low efficiency in DPF filter
  • 3818 - Open load error for power stage
  • 3820 - Over temperature error for H-bridge
  • 3821 - Short circuit to battery on Out1 error for H-bridge
  • 3822 - Short circuit to battery on Out2 error for H-bridge
  • 3823 - Short circuit to ground on Out1 error for H-bridge
  • 3824 - Short circuit to ground on Out2 error for H-bridge
  • 3825 - Short circuit over load error for H-bridge
  • 3826 - Temperature dependent over current error for H-bridge
  • 3827 - Under voltage error for H-bridge
  • 3830 - DFC for valve position sensor physical SRC high
  • 3831 - DFC for valve position sensor physical SRC low
  • 3834 - ECU Power stages: Throttle valve actuator power stage: SRC HighTier
  • 3835 - ECU Power stages: Throttle valve actuator power stage: SRC low
  • 3838 - Oxidation catalyst upstream temperature shorted to high source
  • 3839 - Oxidation catalyst upstream temperature shorted to low source
  • 3840 - Diesel particulate filter upstream temperature sensor shorted to high source
  • 3841 - Diesel particulate filter upstream temperature sensor shorted to low source
  • 3852 - Lambda sensor: The maximum allowed time for blow out is exceeded
  • 4043 - Hydraulic Oil Temperature Sender Short To Ground
  • 4044 - Hydraulic Oil Temperature Sender Open Circuit
  • 4055 - Park Brake Valve (On/Off) - Solenoid Supply Open Circuit
  • 4056 - Park Brake Valve (On/Off) - Solenoid Supply Short to Ground
  • 4057 - Park Brake Valve (On/Off) - Solenoid Supply Short to Power
  • 4061 - Forward Pump Control Valves (Directional) - Solenoid Right (A) Supply Open Circuit
  • 4062 - Forward Pump Control Valves (Directional) - Solenoid Right (A) Supply Short to Ground
  • 4071 - Forward Pump Control Valves (Directional) - Solenoid Left (B) Supply Open Circuit
  • 4072 - Forward Pump Control Valves (Directional) - Solenoid Left (B) Supply Short to Ground
  • 4081 - Forward Pump Control Valves (Directional) - Common Solenoid Return Short to Power
  • 4082 - Forward Pump Control Valves (Directional) - Pumps Forward Solenoids Short to Ground
  • 4083 - Forward Pump Control Valves (Directional) - Common Solenoid Return Open Circuit
  • 4309 - Park Brake Button - Park Brake Button Timeout (30 sec)
  • 4361 - Reverse Pump Control Valves (Directional) - Solenoid Right (A) Supply Open Circuit
  • 4362 - Reverse Pump Control Valves (Directional) - Solenoid Right (A) Supply Short to Ground
  • 4371 - Reverse Pump Control Valves (Directional) - Solenoid Left (B) Supply Open Circuit
  • 4372 - Reverse Pump Control Valves (Directional) - Solenoid Left (B) Supply Short to Ground
  • 4381 - Reverse Pump Control Valves (Directional) - Common Solenoid Return Short to Power
  • 4382 - Reverse Pump Control Valves (Directional) - Pumps Reverse Solenoids Short to Ground
  • 4383 - Reverse Pump Control Valves (Directional) - Common Solenoid Return Open Circuit
  • 4401 - Park Brake (Mechanical Machines) - Park Brake Solenoid - Open Circuit
  • 4402 - Park Brake (Mechanical Machines) - Park Brake Solenoid - Short to Power
  • 4431 - Park Brake Pressure Switch - Pressure Switch (Plausibility Check With Solenoid Valve)
  • 4731 - Right Swash Plate Sensor - Pin A Short to Ground/ Open Circuit
  • 4732 - Right Swash Plate Sensor - Pin A Short to Power
  • 4734 - Right Swash Plate Angle Sensor - Pin B Short to Ground/ Open Circuit
  • 4735 - Right Swash Plate Angle Sensor - Pin B Short to Power
  • 4737 - Right Swash Plate Angle Sensor - In Range Fault
  • 4741 - Left Swash Plate Angle Sensor - Pin A Short to Ground/ Open Circuit
  • 4742 - Left Swash Plate Angle Sensor - Pin A Short to Power
  • 4744 - Left Swash Plate Angle Sensor - Pin B Short to Ground/ Open Circuit
  • 4745 - Left Swash Plate Angle Sensor - Pin B Short to Power
  • 4747 - Left Swash Plate Angle Sensor - In Range Fault
  • 4752 - Left Swash Plate Angle Sensor - Implausible Command, Command Does Not Match With Swash Plate Angle
  • 4754 - Right Swash Plate Angle Sensor - Implausible Command, Command Does Not Match With Swash Plate Angle
  • 4781 - Solenoid Valve - Solenoid Supply Open Circuit
  • 4782 - Solenoid Valve - Solenoid Supply Short to Ground
  • 4783 - Solenoid Valve - Solenoid Supply Short to Power
  • 4951 - Hydraulic Enable (Mechanical Machines) - Hydraulic Interlock Solenoid, Short to Power
  • 4952 - Hydraulic Enable (Mechanical Machines) - Hydraulic Interlock Solenoid Open Circuit
  • 5051 - Loader Pilot Interlock Valve (On/Off) - Solenoid Supply Open Circuit
  • 5052 - Loader Pilot Interlock Valve (On/Off) - Solenoid Supply Short to Ground
  • 5053 - Loader Pilot Interlock Valve (On/Off) - Solenoid Supply Short to Power
  • 5061 - Port Lock Valve (On/Off) - Solenoid Supply Open Circuit
  • 5062 - Port Lock Valve (On/Off) - Solenoid Supply Short to Ground
  • 5063 - Port Lock Valve (On/Off) - Solenoid Supply Short to Power
  • 5121 - Right Joystick F-B Axis - Pin A Short to Power/ Short to Ground/ Open Circuit
  • 5122 - Right Joystick F-B Axis - Pin B Short to Power/ Short to Ground/ Open Circuit
  • 5124 - Right Joystick F-B Axis - In Range Fault
  • 5131 - Right Joystick R-L Axis (ISO/H Pattern) - Pin A Short to Ground/ Open Circuit
  • 5132 - Right Joystick R-L Axis (ISO/H Pattern) - Pin A Short to Power
  • 5134 - Right Joystick R-L Axis (ISO/H Pattern) - Pin B Short to Ground/ Open Circuit
  • 5135 - Right Joystick R-L Axis (ISO/H Pattern) - Pin B Short to Power
  • 5137 - Right Joystick R-L Axis (ISO/H Pattern) - In Range Fault
  • 5141 - Aux Thumbwheel Axis - Pin A Short to Ground/ Open Circuit
  • 5142 - Aux Thumbwheel Axis - Pin A Short to Power
  • 5144 - Aux Thumbwheel Axis - Pin A Short to Ground/ Open Circuit
  • 5145 - Aux Thumbwheel Axis - Pin A Short to Power
  • 5147 - Aux Thumbwheel Axis - In Range Fault
  • 5201 - Left Joystick L-R Axis - Pin A Short to Power/ Short to Ground/ Open Circuit
  • 5202 - Left Joystick L-R Axis - Pin B Short to Power/ Short to Ground/ Open Circuit
  • 5204 - Left Joystick L-R Axis - In Range Fault
  • 5211 - Left Joystick F-B Axis - Pin A Short to Ground/ Open Circuit
  • 5212 - Left Joystick F-B Axis - Pin A Short to Power
  • 5214 - Left Joystick F-B Axis - Pin B Short to Ground/ Open Circuit
  • 5215 - Left Joystick F-B Axis - Pin B Short to Power
  • 5217 - Left Joystick F-B Axis - In Range Fault
  • 5221 - Loader Arm Valve (Directional) - Solenoid Raise A Supply Open Circuit
  • 5222 - Loader Arm Valve (Directional) - Solenoid Raise A Supply Short to Ground
  • 5231 - Loader Arm Valve (Directional) - Solenoid Lower B Supply Open Circuit
  • 5232 - Loader Arm Valve (Directional) - Solenoid Lower B Supply Short to Ground
  • 5241 - Boom Valve (Directional) - Common Solenoid (C) Return Short to Power
  • 5242 - Loader Arm Valve (Directional) - Loader Arm Solenoids Short to Ground
  • 5243 - Boom Valve (Directional) - Common Solenoid (C) Return Open Circuit
  • 5251 - Loader Bucket Valve (Directional) - Solenoid Rollback (A) Supply Open Circuit
  • 5252 - Loader Bucket Valve (Directional) - Solenoid Rollback (A) Supply Short to Ground
  • 5261 - Bucket Valve (Directional) - Solenoid Dump (B) Supply Open Circuit
  • 5262 - Bucket Valve (Directional) - Solenoid Dump (B) Supply Short to Ground
  • 5271 - Bucket Valve (Directional) - Common Solenoid (C) Return Short to Power
  • 5272 - Loader Bucket Valve (Directional) - Loader Bucket Solenoids Short to Ground
  • 5273 - Bucket Valve (Directional) - Common Solenoid (C) Return Open Circuit
  • 5281 - Aux Valve (Directional) - Solenoid Forward (A) Supply Open Circuit
  • 5282 - Aux Valve (Directional) - Solenoid Forward (A) Supply Short to Ground
  • 5291 - Aux Valve (Directional) - Solenoid Reverse (B) Supply Open Circuit
  • 5292 - Aux Valve (Directional) - Solenoid Reverse (B) Supply Short to Ground
  • 5309 - Float Button - Float Button Timeout (30 sec)
  • 5313 - EHF Enable Switch - STP
  • 5323 - EHF Fwd / Rev Switch - STP
  • 5371 - EHF Pump Control PRV's (Directional) - Forward Solenoid (A) Supply Open Circuit
  • 5372 - EHF Pump Control PRV's (Directional) - Forward Solenoid (A) Supply Short to Ground
  • 5381 - EHF Pump Control PRV's (Directional) - Reverse Solenoid (B) Supply Open Circuit
  • 5382 - EHF Pump Control PRV's (Directional) - Reverse Solenoid (B) Supply Short to Ground
  • 5391 - EHF Pump Control PRV's (Directional) - Solenoids Return Open Circuit
  • 5392 - EHF Pump Control PRV's (Directional) - EHF Pumps Solenoids Short to Ground
  • 5393 - EHF Pump Control PRV's (Directional) - EHF Pumps Solenoids Short to Power
  • 5409 - CAN Message Error - Aux Override Disabled Due To Aux Override Button Timeout (30 sec)
  • 5501 - Loader Arm Spool Sensor - Sensor Short to Ground/ Open Circuit
  • 5502 - Loader Arm Spool Sensor - Sensor Short to Power
  • 5503 - Hydraulic Enable (Mechanical Machines) - EH AUX Output, Short to Power
  • 5504 - Bucket Valve Spool Sensor - Sensor Short to Ground/ Open Circuit
  • 5505 - Bucket Valve Spool Sensor - Sensor Short to Power
  • 5507 - Auxiliary Valve Spool Sensor - Sensor Short to Ground/ Open Circuit
  • 5508 - Auxiliary Valve Spool Sensor - Sensor Short to Power
  • 5511 - Loader Arm Spool Sensor - Implausible State Sensor vs. Loader Arm Command, Stuck Spool/ PRV
  • 5512 - Bucket Valve Spool Sensor - Implausible State Sensor vs. Loader Bucket Command
  • 5513 - Auxiliary Valve Spool Sensor - Implausible State Sensor vs. Auxiliary Command
  • 5601 - Aux Valve (Directional) - Common Solenoid Return Short to Power
  • 5602 - Loader Auxiliary Valve (Directional) - Loader Auxiliary Solenoids Short to Ground
  • 5603 - Loader Auxiliary Valve Solenoid Return Open Circuit
  • 5701 - Pattern Switch - Short to Ground/ Open Circuit
  • 5703 - Pattern Switch - Short to Power
  • 5811 - Loader Lockout Switch - Implausible State
  • 9003 - CAN - J1939 Receive Buffer - Buffer Overflow
  • 9004 - Memory Error - Triple Redundant: Hour Meter - Location 1 Corrupt
  • 9005 - Memory Error - Triple Redundant: Hour Meter - Location 2 Corrupt
  • 9006 - Memory Error - Triple Redundant: Hour Meter - Location 3 Corrupt
  • 9151 - CAN Connection: CAN Communication Timed Out After 5 Seconds
  • 9152 - CAN Connection - CAN Communication Timed Out After 5 Seconds
  • 9158 - H-Pattern Indicator Short to Ground
  • 9159 - ISO-Pattern Indicator Short to Ground
  • 9160 - H-Pattern Indicator Short to Power
  • 9161 - ISO-Pattern Indicator Short to Power
  • 9401 - Memory Error - Double Redundant: Memory Corruption Detected and Repaired
  • 9403 - Memory Error - Double Redundant: Unrecoverable Memory Corruption Operable
  • 9404 - Memory Error - Triple Redundant: Hour Meter - Hour Meter Failure
  • 9405 - CAN - DM1 (EH Machines): Loss Of DM1 Message From UCM
  • 9406 - CAN - Can Communication Lost (EH Machines): Loss Of All CAN Communication From UCM
  • 9407 - Memory Error - ID Errors: Unrecoverable Hardware ID
  • 9408 - Memory Error - ID Errors: Unrecoverable Panel ID

Fault Code list ordered by Fault Codes
  • 1002 - Engine Coolant Temperature Sender - Over Temperature >110° C
  • 1004 - Hydraulic Filter Restriction Switch - Hydraulic Filter Restricted
  • 1009 - Hydraulic Oil Temperature Sender - Over Temperature >210° F
  • 1014 - Cluster Battery Monitor: Over Voltage > 16.5 volts
  • 1015 - Cluster Battery Monitor: Under Voltage < 11.5 volts
  • 1025 - Throttle Sensor - Out Of Range Short to Power
  • 1030 - Throttle Sensor - Out Of Range Short to Ground/ Open Circuit
  • 1041 - RPM Monitoring - Over Speed
  • 1045 - Fuel Level Sensor Open Circuit
  • 1202 - RPM Monitoring - Over Speed (Max)
  • 1203 - RPM Monitoring - Open Circuit/ Short to Ground/ Short to Power
  • 1205 - Hydraulic Enable (EH Machines) - Hydraulic Enable Output, Short to Power
  • 1206 - CAN Connection: Configuration Response Timeout
  • 1207 - Memory Parameters - Invalid Configuration Between IC and UCM
  • 1208 - Seat Switch - Plausibility Fault
  • 1211 - Calibration Functions - Joystick Calibration Not Complete
  • 1212 - Calibration Functions - Ground Drive Calibration Not Complete
  • 1213 - Calibration Functions - Loader Valve Calibration Not Complete
  • 1214 - Calibration Functions - Throttle Calibration Not Complete
  • 1221 - Health Monitor Functions - UCM - UCM Temperature / Current Draw Over Limit
  • 1222 - Health Monitor Functions - UCM - UCM Sustained Over Temperature Limit
  • 1223 - Health Monitor Functions - UCM - UCM Sustained Over Current Limit
  • 1224 - Health Monitor Functions - UCM - Internal Memory or Core Monitoring Fault
  • 1225 - Health Monitor Functions - UCM - EEPROM Memory Checksum Fault
  • 1350 - Hyd Enable Switch - Implausible State (Hardwire vs CAN)
  • 1511 - Right Brake Lights Open Circuit
  • 1512 - Right Brake Lights Short to Ground
  • 1513 - Right Brake Lights Short to Power
  • 1521 - Left Brake Lights Open Circuit
  • 1522 - Left Brake Lights Short to Ground
  • 1523 - Left Brake Lights Short to Power
  • 1532 - Backup Alarm - Short to Ground
  • 1533 - Backup Alarm - Short to Power
  • 1900 - UCM - UCM Ground Fault
  • 1901 - UCM - UCM Supply Voltage High
  • 1902 - UCM - UCM Supply Voltage Low
  • 1903 - UCM - UCM Supply Voltage Below Operational Limit
  • 1904 - UCM - Rail 12VB: 5V Regulators Supply Input Power Off
  • 1905 - UCM - 5VREF1 Sensor Supply Voltage Out of Range
  • 1906 - UCM - 5VREF3 Sensor Supply Voltage Out of Range
  • 1907 - UCM - Rail 12VF1: Aux Retract Input Power Off
  • 1908 - UCM - Rail 12VF2: Bucket Extend Input Power Off
  • 1909 - UCM - Rail 12VF3: Boom Raise/Lower Input Power Off
  • 1910 - UCM - Rail 12VH: Ldr Plt Interlk & Port Lock Input Power Off
  • 1911 - UCM - Rail 12VH1: Left & Right Pump Reverse Input Power Off
  • 1912 - UCM - Rail 12VM: Left & Right Brake Lights & Aux Extend Input Power Off
  • 1913 - UCM - Rail 12VS1: Bucket Curl Input Power Off
  • 1914 - UCM - Rail 12VS2: Backup Alarm Input Power Off
  • 1915 - UCM - Rail 12VT1: Two Speed Input Power Off
  • 1916 - UCM - Rail 12VU1: Right & Left Pumps Forward Input Power Off
  • 1917 - UCM - Rail 12VU2: Park Brake Solenoid Input Power Off
  • 3007 - Engine Coolant Temperature Sender - Short to Ground
  • 3008 - Engine Coolant Temperature Sender - Open Circuit
  • 3027 - Oil pressure signal not plausible
  • 3403 - Starter: Starter is cranked > 30s
  • 3405 - ECU Power stages: Open load temperature error on the Turbocharger PWM output power stage
  • 3406 - ECU Power stages: Over temperature error on the Turbocharger PWM output power stage
  • 3408 - Lambda sensor: Oxygen concentration implausibly high
  • 3409 - Oil pressure too low
  • 3410 - Permanent governor deviation for valve
  • 3411 - Permanent governor deviation for valve
  • 3414 - Short circuit in cylinder 1 glow plug
  • 3415 - Short circuit in cylinder 2 glow plug
  • 3416 - Short circuit in cylinder 3 glow plug
  • 3417 - Short circuit in cylinder 4 glow plug
  • 3418 - ECU Power stages: SCB error on the Turbocharger PWM output power stage
  • 3419 - ECU Power stages: SCG error on the Turbocharger PWM output power stage
  • 3425 - Turbocharger: Over boost deviation at P2 too high in pressure charger regulator
  • 3426 - Low efficiency in DPF filter
  • 3427 - Diesel particulate filter (DPF): Signal range check flow resistance of the particulate filter - low
  • 3428 - Diesel Particulate Filter Pressure sensor: not plausibility error
  • 3429 - Diesel Particulate filter Pressure sensor: hoseline plausibility error
  • 3648 - EVGT Boost pressure monitoring for over boost
  • 3657 - Timeout Error of CAN-Receive-Frame CM1BC
  • 3659 - Battery voltage: Power stage diagnosis could be disabled due to high battery voltage
  • 3660 - Battery voltage: Power stage diagnosis could be disabled due to low Battery voltage
  • 3663 - EGR command saturation over higher threshold
  • 3664 - EGR command saturation over lower threshold
  • 3665 - Permanent governor deviation for valve
  • 3666 - Permanent governor deviation for valve
  • 3667 - Open load error for power stage
  • 3668 - Over temperature error for H-bridge
  • 3669 - Short circuit to battery on Out1 error for H-bridge
  • 3670 - Short circuit to battery on Out2 error for H-bridge
  • 3671 - Short circuit to ground on Out1 error for H-bridge
  • 3672 - Short circuit to ground on Out2 error for H-bridge
  • 3673 - Short circuit over load error for H-bridge
  • 3674 - Under voltage error for H-bridge
  • 3675 - DFC for long time valve drift at closed position
  • 3676 - DFC for valve position sensor voltage SRC high
  • 3677 - DFC for valve position sensor voltage SRC low
  • 3689 - Faulty diagnostic data transmission or protocol error
  • 3691 - No load error for low voltage system
  • 3692 - Over temperature error on ECU power stage for glow plug low voltage system
  • 3693 - Short circuit to battery error for low voltage system
  • 3694 - Short circuit to ground error for low voltage system
  • 3695 - Failure in glow plug cylinder 1
  • 3696 - Failure in glow plug cylinder 2
  • 3697 - Failure in glow plug cylinder 3
  • 3698 - Failure in glow plug cylinder 4
  • 3702 - Injection control: Detection of failed engine start
  • 3703 - Injection control: check of minimum rail pressure
  • 3704-3706 - Injector adjustment programming: check of missing injector adjustment value programming
  • 3707 - Lambda sensor: Open circuit at the lambda sensor Nernst cell pin
  • 3708 - Lambda sensor: Open circuit at the lambda sensor pump current pin
  • 3709 - Lambda sensor: Open circuit at the lambda sensor virtual ground pin
  • 3710 - Lambda sensor: Fault to indicate dynamics of the sensor signal too small
  • 3711 - SCB error of the LSU Heater Power stage
  • 3712 - Lambda sensor: SCG error of the LSU heater power stage
  • 3713 - Lambda sensor: Open Load error of the LSU Heater Power stage
  • 3714 - Lambda sensor: Fault code to indicate SRC High error for O2 calibration
  • 3715 - Lambda sensor: SRC Low error for O2 calibration
  • 3716 - Lambda sensor: O2 value above the max threshold
  • 3720 - Lambda sensor: Low battery voltage at the SPI chip
  • 3721 - Lambda sensor: Fault check to indicate SPI chip error of lambda sensor
  • 3722 - Lambda sensor: LSU sensor temperature Ri exceeds the maximum limit
  • 3723 - Lambda sensor: LSU sensor temperature Ri is below the minimum limit
  • 3724 - Lambda sensor: Short to battery at IA, IP, UN, VG
  • 3725 - Lambda sensor: Short to ground at IA, IP, UN, VG
  • 3736 - O2 concentration is outside the predefined window during Heater coupling detection
  • 3737 - Lambda sensor: Over temperature error of the LSU Heater Power stage
  • 3766 - Diesel particulate filter pressure sensor: Fault check for the pressure sensor plausibility
  • 3771 - Oxidation Catalyst: Up and down stream temperature sensors in Oxidation catalysts exchanged
  • 3773 - EVGT Turbocharger Control Underboost Pressure failure
  • 3786 - Diesel particulate filter signal range check is high
  • 3787 - Diesel particulate filter (DPF) : Signal range check flow resistance of the particulate filter - very high
  • 3789 - Regeneration duration exceeds maximum allowed duration
  • 3790 - Diesel particulate filter: Signal range check flow resistance of the particulate filter - max
  • 3794 - Intake air pressure sensor: Plausibility check for air pressure at the upstream of intake valve sensor
  • 3795 - Intake air pressure sensor: Plausibility check for air pressure at the upstream of intake valve sensor
  • 3796 - Diesel particulate filter pressure sensor hose line error
  • 3798 - Diesel particulate filter pressure sensor: SRC low for differential pressure sensor
  • 3799 - Pressure Relief valve: pressure relief valve is forced to open, perform pressure shock
  • 3800 - Pressure relief valve: Quantity balance check if a successful PRV opening is ensured
  • 3801 - Turbine upstream pressure sensor: SRC high for turbine upstream pressure sensor
  • 3802 - Turbine upstream pressure sensor: SRC low for turbine upstream pressure sensor
  • 3815 - Low efficiency in DPF filter
  • 3818 - Open load error for power stage
  • 3820 - Over temperature error for H-bridge
  • 3821 - Short circuit to battery on Out1 error for H-bridge
  • 3822 - Short circuit to battery on Out2 error for H-bridge
  • 3823 - Short circuit to ground on Out1 error for H-bridge
  • 3824 - Short circuit to ground on Out2 error for H-bridge
  • 3825 - Short circuit over load error for H-bridge
  • 3826 - Temperature dependent over current error for H-bridge
  • 3827 - Under voltage error for H-bridge
  • 3830 - DFC for valve position sensor physical SRC high
  • 3831 - DFC for valve position sensor physical SRC low
  • 3834 - ECU Power stages: Throttle valve actuator power stage: SRC HighTier
  • 3835 - ECU Power stages: Throttle valve actuator power stage: SRC low
  • 3838 - Oxidation catalyst upstream temperature shorted to high source
  • 3839 - Oxidation catalyst upstream temperature shorted to low source
  • 3840 - Diesel particulate filter upstream temperature sensor shorted to high source
  • 3841 - Diesel particulate filter upstream temperature sensor shorted to low source
  • 3852 - Lambda sensor: The maximum allowed time for blow out is exceeded
  • 4043 - Hydraulic Oil Temperature Sender Short To Ground
  • 4044 - Hydraulic Oil Temperature Sender Open Circuit
  • 4055 - Park Brake Valve (On/Off) - Solenoid Supply Open Circuit
  • 4056 - Park Brake Valve (On/Off) - Solenoid Supply Short to Ground
  • 4057 - Park Brake Valve (On/Off) - Solenoid Supply Short to Power
  • 4061 - Forward Pump Control Valves (Directional) - Solenoid Right (A) Supply Open Circuit
  • 4062 - Forward Pump Control Valves (Directional) - Solenoid Right (A) Supply Short to Ground
  • 4071 - Forward Pump Control Valves (Directional) - Solenoid Left (B) Supply Open Circuit
  • 4072 - Forward Pump Control Valves (Directional) - Solenoid Left (B) Supply Short to Ground
  • 4081 - Forward Pump Control Valves (Directional) - Common Solenoid Return Short to Power
  • 4082 - Forward Pump Control Valves (Directional) - Pumps Forward Solenoids Short to Ground
  • 4083 - Forward Pump Control Valves (Directional) - Common Solenoid Return Open Circuit
  • 4309 - Park Brake Button - Park Brake Button Timeout (30 sec)
  • 4361 - Reverse Pump Control Valves (Directional) - Solenoid Right (A) Supply Open Circuit
  • 4362 - Reverse Pump Control Valves (Directional) - Solenoid Right (A) Supply Short to Ground
  • 4371 - Reverse Pump Control Valves (Directional) - Solenoid Left (B) Supply Open Circuit
  • 4372 - Reverse Pump Control Valves (Directional) - Solenoid Left (B) Supply Short to Ground
  • 4381 - Reverse Pump Control Valves (Directional) - Common Solenoid Return Short to Power
  • 4382 - Reverse Pump Control Valves (Directional) - Pumps Reverse Solenoids Short to Ground
  • 4383 - Reverse Pump Control Valves (Directional) - Common Solenoid Return Open Circuit
  • 4401 - Park Brake (Mechanical Machines) - Park Brake Solenoid - Open Circuit
  • 4402 - Park Brake (Mechanical Machines) - Park Brake Solenoid - Short to Power
  • 4431 - Park Brake Pressure Switch - Pressure Switch (Plausibility Check With Solenoid Valve)
  • 4731 - Right Swash Plate Sensor - Pin A Short to Ground/ Open Circuit
  • 4732 - Right Swash Plate Sensor - Pin A Short to Power
  • 4734 - Right Swash Plate Angle Sensor - Pin B Short to Ground/ Open Circuit
  • 4735 - Right Swash Plate Angle Sensor - Pin B Short to Power
  • 4737 - Right Swash Plate Angle Sensor - In Range Fault
  • 4741 - Left Swash Plate Angle Sensor - Pin A Short to Ground/ Open Circuit
  • 4742 - Left Swash Plate Angle Sensor - Pin A Short to Power
  • 4744 - Left Swash Plate Angle Sensor - Pin B Short to Ground/ Open Circuit
  • 4745 - Left Swash Plate Angle Sensor - Pin B Short to Power
  • 4747 - Left Swash Plate Angle Sensor - In Range Fault
  • 4752 - Left Swash Plate Angle Sensor - Implausible Command, Command Does Not Match With Swash Plate Angle
  • 4754 - Right Swash Plate Angle Sensor - Implausible Command, Command Does Not Match With Swash Plate Angle
  • 4781 - Solenoid Valve - Solenoid Supply Open Circuit
  • 4782 - Solenoid Valve - Solenoid Supply Short to Ground
  • 4783 - Solenoid Valve - Solenoid Supply Short to Power
  • 4951 - Hydraulic Enable (Mechanical Machines) - Hydraulic Interlock Solenoid, Short to Power
  • 4952 - Hydraulic Enable (Mechanical Machines) - Hydraulic Interlock Solenoid Open Circuit
  • 5051 - Loader Pilot Interlock Valve (On/Off) - Solenoid Supply Open Circuit
  • 5052 - Loader Pilot Interlock Valve (On/Off) - Solenoid Supply Short to Ground
  • 5053 - Loader Pilot Interlock Valve (On/Off) - Solenoid Supply Short to Power
  • 5061 - Port Lock Valve (On/Off) - Solenoid Supply Open Circuit
  • 5062 - Port Lock Valve (On/Off) - Solenoid Supply Short to Ground
  • 5063 - Port Lock Valve (On/Off) - Solenoid Supply Short to Power
  • 5121 - Right Joystick F-B Axis - Pin A Short to Power/ Short to Ground/ Open Circuit
  • 5122 - Right Joystick F-B Axis - Pin B Short to Power/ Short to Ground/ Open Circuit
  • 5124 - Right Joystick F-B Axis - In Range Fault
  • 5131 - Right Joystick R-L Axis (ISO/H Pattern) - Pin A Short to Ground/ Open Circuit
  • 5132 - Right Joystick R-L Axis (ISO/H Pattern) - Pin A Short to Power
  • 5134 - Right Joystick R-L Axis (ISO/H Pattern) - Pin B Short to Ground/ Open Circuit
  • 5135 - Right Joystick R-L Axis (ISO/H Pattern) - Pin B Short to Power
  • 5137 - Right Joystick R-L Axis (ISO/H Pattern) - In Range Fault
  • 5141 - Aux Thumbwheel Axis - Pin A Short to Ground/ Open Circuit
  • 5142 - Aux Thumbwheel Axis - Pin A Short to Power
  • 5144 - Aux Thumbwheel Axis - Pin A Short to Ground/ Open Circuit
  • 5145 - Aux Thumbwheel Axis - Pin A Short to Power
  • 5147 - Aux Thumbwheel Axis - In Range Fault
  • 5201 - Left Joystick L-R Axis - Pin A Short to Power/ Short to Ground/ Open Circuit
  • 5202 - Left Joystick L-R Axis - Pin B Short to Power/ Short to Ground/ Open Circuit
  • 5204 - Left Joystick L-R Axis - In Range Fault
  • 5211 - Left Joystick F-B Axis - Pin A Short to Ground/ Open Circuit
  • 5212 - Left Joystick F-B Axis - Pin A Short to Power
  • 5214 - Left Joystick F-B Axis - Pin B Short to Ground/ Open Circuit
  • 5215 - Left Joystick F-B Axis - Pin B Short to Power
  • 5217 - Left Joystick F-B Axis - In Range Fault
  • 5221 - Loader Arm Valve (Directional) - Solenoid Raise A Supply Open Circuit
  • 5222 - Loader Arm Valve (Directional) - Solenoid Raise A Supply Short to Ground
  • 5231 - Loader Arm Valve (Directional) - Solenoid Lower B Supply Open Circuit
  • 5232 - Loader Arm Valve (Directional) - Solenoid Lower B Supply Short to Ground
  • 5241 - Boom Valve (Directional) - Common Solenoid (C) Return Short to Power
  • 5242 - Loader Arm Valve (Directional) - Loader Arm Solenoids Short to Ground
  • 5243 - Boom Valve (Directional) - Common Solenoid (C) Return Open Circuit
  • 5251 - Loader Bucket Valve (Directional) - Solenoid Rollback (A) Supply Open Circuit
  • 5252 - Loader Bucket Valve (Directional) - Solenoid Rollback (A) Supply Short to Ground
  • 5261 - Bucket Valve (Directional) - Solenoid Dump (B) Supply Open Circuit
  • 5262 - Bucket Valve (Directional) - Solenoid Dump (B) Supply Short to Ground
  • 5271 - Bucket Valve (Directional) - Common Solenoid (C) Return Short to Power
  • 5272 - Loader Bucket Valve (Directional) - Loader Bucket Solenoids Short to Ground
  • 5273 - Bucket Valve (Directional) - Common Solenoid (C) Return Open Circuit
  • 5281 - Aux Valve (Directional) - Solenoid Forward (A) Supply Open Circuit
  • 5282 - Aux Valve (Directional) - Solenoid Forward (A) Supply Short to Ground
  • 5291 - Aux Valve (Directional) - Solenoid Reverse (B) Supply Open Circuit
  • 5292 - Aux Valve (Directional) - Solenoid Reverse (B) Supply Short to Ground
  • 5309 - Float Button - Float Button Timeout (30 sec)
  • 5371 - EHF Pump Control PRV's (Directional) - Forward Solenoid (A) Supply Open Circuit
  • 5372 - EHF Pump Control PRV's (Directional) - Forward Solenoid (A) Supply Short to Ground
  • 5381 - EHF Pump Control PRV's (Directional) - Reverse Solenoid (B) Supply Open Circuit
  • 5382 - EHF Pump Control PRV's (Directional) - Reverse Solenoid (B) Supply Short to Ground
  • 5391 - EHF Pump Control PRV's (Directional) - Solenoids Return Open Circuit
  • 5392 - EHF Pump Control PRV's (Directional) - EHF Pumps Solenoids Short to Ground
  • 5393 - EHF Pump Control PRV's (Directional) - EHF Pumps Solenoids Short to Power
  • 5409 - CAN Message Error - Aux Override Disabled Due To Aux Override Button Timeout (30 sec)
  • 5501 - Loader Arm Spool Sensor - Sensor Short to Ground/ Open Circuit
  • 5502 - Loader Arm Spool Sensor - Sensor Short to Power
  • 5503 - Hydraulic Enable (Mechanical Machines) - EH AUX Output, Short to Power
  • 5504 - Bucket Valve Spool Sensor - Sensor Short to Ground/ Open Circuit
  • 5505 - Bucket Valve Spool Sensor - Sensor Short to Power
  • 5507 - Auxiliary Valve Spool Sensor - Sensor Short to Ground/ Open Circuit
  • 5508 - Auxiliary Valve Spool Sensor - Sensor Short to Power
  • 5511 - Loader Arm Spool Sensor - Implausible State Sensor vs. Loader Arm Command, Stuck Spool/ PRV
  • 5512 - Bucket Valve Spool Sensor - Implausible State Sensor vs. Loader Bucket Command
  • 5513 - Auxiliary Valve Spool Sensor - Implausible State Sensor vs. Auxiliary Command
  • 5601 - Aux Valve (Directional) - Common Solenoid Return Short to Power
  • 5602 - Loader Auxiliary Valve (Directional) - Loader Auxiliary Solenoids Short to Ground
  • 5603 - Loader Auxiliary Valve Solenoid Return Open Circuit
  • 5701 - Pattern Switch - Short to Ground/ Open Circuit
  • 5703 - Pattern Switch - Short to Power
  • 5811 - Loader Lockout Switch - Implausible State
  • 9004 - Memory Error - Triple Redundant: Hour Meter - Location 1 Corrupt
  • 9005 - Memory Error - Triple Redundant: Hour Meter - Location 2 Corrupt
  • 9006 - Memory Error - Triple Redundant: Hour Meter - Location 3 Corrupt
  • 9151 - CAN Connection: CAN Communication Timed Out After 5 Seconds
  • 9152 - CAN Connection - CAN Communication Timed Out After 5 Seconds
  • 9158 - H-Pattern Indicator Short to Ground
  • 9159 - ISO-Pattern Indicator Short to Ground
  • 9160 - H-Pattern Indicator Short to Power
  • 9161 - ISO-Pattern Indicator Short to Power
  • 9401 - Memory Error - Double Redundant: Memory Corruption Detected and Repaired
  • 9403 - Memory Error - Double Redundant: Unrecoverable Memory Corruption Operable
  • 9404 - Memory Error - Triple Redundant: Hour Meter - Hour Meter Failure
  • 9405 - CAN - DM1 (EH Machines): Loss Of DM1 Message From UCM
  • 9406 - CAN - Can Communication Lost (EH Machines): Loss Of All CAN Communication From UCM
  • 9407 - Memory Error - ID Errors: Unrecoverable Hardware ID
  • 9408 - Memory Error - ID Errors: Unrecoverable Panel ID
  • [EGR] - 111 - EGR potentiometer valve could not be completely opened
  • [EGR] - 112 - EGR potentiometer valve could not be completely closed
  • [EGR] - 119 - Engine crank signal present for 300 seconds
  • [EGR] - 126 - Battery voltage fault
  • [EGR] - 131 - Coolant temperature sensor fault
  • [EGR] - 134 - Intake air pressure sensor fault
  • [EGR] - 141 - Engine speed sensor fault
  • [EGR] - 186 - EGR valve position sensor fault
  • [EGR] - 189 - EGR valve position driver fault
  • [EGR] - 1E5 - Sensor voltage supply fault
  • [EGR] - 2E5 - Sensor ground fault
  • [IC] - 1201 - Hydraulic Filter Restriction Switch - OC
  • [IC] - 1204 - Start Sequence - Key Switch State - Engine Running Plausability Fault
  • [IC] - 3000 - Engine Malfunction - ECU Fault - General/Undefined/Air Filter Restriction
  • [IC] - 3028 - Engine Oil Pressure Switch - Engine Oil Pressure Low
  • [IC] - 3029 - Engine Oil Pressure Switch - Engine Oil Pressure Switch OC
  • [IC] - 3156 - Engine Preheat - Glow Plug - OC
  • [IC] - 3401 - Engine Start - Fuel Solenoid - STP
  • [IC] - 3402 - Engine Start - Fuel Solenoid - OC
  • [IC] - 3404 - Starter - STP
  • [IC] - 3405 - Starter - STG / OC
  • [IC] - 9003 - CAN - J1939 Receive Buffer - Buffer Overflow
  • [UCM] - 1905 - UCM - 5VREF1 Sensor Supply Voltage Out of Range
  • [UCM] - 1906 - UCM - 5VREF3 Sensor Supply Voltage Out of Range
  • [UCM] - 3154 - Engine Preheat - Glow Plug - STP
  • [UCM] - 5313 - EHF Enable Switch - STP
  • [UCM] - 5323 - EHF Fwd / Rev Switch - STP
  • [UCM] - 5392 - EHF Pump Control PRV's (Directional) - EHF Pumps Solenoids Short to Ground
  • [UCM] - 5811 - Loader Lockout Switch - Implausible State

               ---------------------------------------------------------------------------
Ниже приводится пример расшифровки кодов
доступных только пользователям
---------------------------------------------------------------------------

FAULT CODE 1002 - Engine Coolant Temperature Sender - 
Over Temperature >110° C
1002 - Engine Coolant Temperature Sender - Over Temperature >110° C
Context: Diagnostic Trouble Code 1002 has an error priority of Engine-Amber.
There are no restrictions with Diagnostic Trouble Code 1002.
Cause:
Instrument Cluster has sensed that the Engine Coolant Temperature is high. (The fault is only activated when code 3007 is not active, Ignition is On, Start input is low, and temperature is greater than110 °C (230.0 °F).)
Possible failure modes:
  • Shorted wire in circuit.
  • Failed Engine Coolant Temperature Sender.
  • Failed Instrument Cluster.

Solution:
1: Use the machine to recreate conditions for error. Use the EST to verify 1002 - Engine Coolant Temperature Sender - Over Temperature >110° C is active. Verify correct mechanical operation of the Engine Coolant System before troubleshooting this fault electrically.
  • A. If the fault is active, continue with step 2.
  • B. If the fault is not active, the fault may be intermittent and not currently active, continue with step 3.

2: Check for proper resistance in the Engine Coolant Temperature Sender. Disconnect connector X-504 (F5C) X-516 (ISM) from the Engine Coolant Temperature Sender. Using a multi-meter, check for resistance between Engine Coolant Temperature Sender pin 1 and ground.
  • A. If resistance is more than 134.4 Ω, continue with step 3.
  • B. If resistance is less than 134.4 Ω, and the engine coolant is not overheated, the Engine Coolant Temperature Sender has failed. Replace the Engine Coolant Temperature Sender.

3: Visually inspect the relevant harnesses and connectors for damage, bent or dislocated pins, corroded terminals or broken wires. Verify that the connectors are fully installed. Flex the harnesses involved to reveal intermittent breaks or shorts in the wiring concerned. Operate the machine while monitoring the EST and Display. Investigate nearby wiring.
  • A. If damage is found or other than normal display readings are indicated, repair the damage discovered during the inspection or locate and repair the other than normal display condition and verify that the error has been resolved.
  • B. If no damage or other than normal display readings are indicated, erase the Diagnostic Trouble Code and continue operation.
Назад к содержимому