GR-300E-1, GR-300E-2, GR-500E-2, GR-550E-1, GR-600E-2, GR-700E-1, GR-750-2, GR-800E-2



Upper unit errors
01 Failure in the main speed sensor. 1.
Gears in transmission are not shifted with the gearshift leaver in "D". 2.
Speedometer does not work 

02 Failure in the sub‐speed sensor.
Downshift not possible

03 Failure in main speed sensor (when gearshift is in "N")

04 Failure in outrigger data (FL)

05 Failure in outrigger data (FR)

06 Failure in outrigger data (RL)

07 Failure in outrigger data (RR)

08 Abnormal torque converter pressure data

09 Abnormal air pressure data

10 Failure in accelerator sonsor 1 data

11 Failure in accelerator sensor 2 data

12 Failure in idle volume data

13 Failure in the upper A/D conversion

15 Upper unit RAM check error

18 Upper unit ROM check error

24 Failure in the transmission input signal combination (Actual transmission and gearshift lever position are not matched).

25 Failure in the transmission input signal.
(Actual transmission and gearshift lever position are not matched).

27 Failure in steering more input signal combination

30 Input value from main speed sensor is unusually high. 1. Speedometer indicates abnormally high speed. 2.
Over speed warning buzzer sounds continuously.

31 Interrupted communication from lower to upper unit

32 Faulty communication from lower to upper unit

33 Interrupted communication from AML to upper unit

34 Failure in RAM for main speed data

35 Faulty communication from AML to upper unit

38 Interrupted communication from meter controller to upper unit

39 Faulty communication from meter controller to upper unit

3A Short circuit dtected by the upper unit, occurring in the communication cable from upper unit to lower unit or from the lower unit to upper unit

48 ECU failure malfunction (it is not possible to run) DIAG 1 (red) in lower unit relay box lights

49 ECU warning malfunction (it is possible to run) DIAG 2 (amber) in lower unit relay box lights

Lower unit errors
16 Lower unit RAM check error

17 Failure in the lower A/D conversion

19 Lower unt ROM check error

28 Interrupted communication from STME to lower unit

29 Faulty communication from STM‐E to lower unit

36 Interrupted communication from upper to lower unit

37 Faulty communication from upper to lower unit

47 Faulty STM‐E

61 Failure in lower unit output power supply 1

62 Failure in lower unit output power supply 2

63 Failure in lower unit output power supply 3

64 Failure in lower unit output power supply 4

65 Failure in lower unit output power supply 5

66 Failure in lower unit output power supply 6

67 Failure in lower unit output power supply 7

68 Failure in lower unit output power supply 8

69 Failure in lower unit output power supply 9

70 Failure in lower unit output power supply 10

71 Failure in lower unit output power supply 11

72 Failure in lower unit output power supply 12

73 Failure in lower unit output power supply 13

74 Failure in lower unit output power supply 14

75 Failure in lower unit output power supply 15

76 Failure in lower unit output power supply 16

80 Monitored lower unit output data is unstable

90 Faulty RY1 output Monitored data ON while output data is OFF

91 Faulty RY2 output Monitored data ON while output data is OFF

92 Faulty RY3 output Monitored data ON while output data is OFF

93 Faulty RY4 output Monitored data ON while output data is OFF

94 Faulty RY5 output Monitored data ON while output data is OFF

95 Faulty RY6 output Monitored data ON while output data is OFF

96 Faulty RY7 output Monitored data ON while output data is OFF

97 Faulty RY8 output Monitored data ON while output data is OFF

98 Faulty RY1 output Monitored data OFF while output data is ON

99 Faulty RY2 output Monitored data OFF while output data is ON

9A Faulty RY3 output Monitored data OFF while output data is ON

9b Faulty RY4 output Monitored data OFF while output data is ON

9C Faulty RY5 output Monitored data OFF while output data is ON

9d Faulty RY6 output Monitored data OFF while output data is ON

9E Faulty RY7 output Monitored data OFF while output data is ON

9F Faulty RY8 output Monitored data OFF while output data is ON

A0 Faulty RY9 output Monitored data ON while output data is OFF

A1 Faulty RY10 output Monitored data ON while output data is OFF

A2 Faulty RY11 output Monitored data ON while output data is OFF

A3 Faulty RY12 output Monitored data ON while output data is OFF

A4 Faulty RY13 output Monitored data ON while output data is OFF

A5 Faulty RY14 output Monitored data ON while output data is OFF

A6 Faulty RY15 output Monitored data ON while output data is OFF

A7 Faulty RY16 output Monitored data ON while output data is OFF

A8 Faulty RY9 output Monitored data OFF while output data is ON