См. также:
MDT 9 Коды неисправностей TADANO серии
GR-300E-1, GR-300E-2, GR-500E-2, GR-550E-1, GR-600E-2, GR-700E-1, GR-750-2, GR-800E-2

Upper unit errors
01 Failure in the main speed sensor. 1.
Gears in transmission are not shifted with the gearshift leaver in "D". 2.
Speedometer does not work
02 Failure in the sub‐speed sensor.
Downshift not possible
03 Failure in main speed sensor (when gearshift is in "N")
04 Failure in outrigger data (FL)
05 Failure in outrigger data (FR)
06 Failure in outrigger data (RL)
07 Failure in outrigger data (RR)
08 Abnormal torque converter pressure data
09 Abnormal air pressure data
10 Failure in accelerator sonsor 1 data
11 Failure in accelerator sensor 2 data
12 Failure in idle volume data
13 Failure in the upper A/D conversion
15 Upper unit RAM check error
18 Upper unit ROM check error
24 Failure in the transmission input signal combination (Actual transmission and gearshift lever position are not matched).
25 Failure in the transmission input signal.
(Actual transmission and gearshift lever position are not matched).
27 Failure in steering more input signal combination
30 Input value from main speed sensor is unusually high. 1. Speedometer indicates abnormally high speed. 2.
Over speed warning buzzer sounds continuously.
31 Interrupted communication from lower to upper unit
32 Faulty communication from lower to upper unit
33 Interrupted communication from AML to upper unit
34 Failure in RAM for main speed data
35 Faulty communication from AML to upper unit
38 Interrupted communication from meter controller to upper unit
39 Faulty communication from meter controller to upper unit
3A Short circuit dtected by the upper unit, occurring in the communication cable from upper unit to lower unit or from the lower unit to upper unit
48 ECU failure malfunction (it is not possible to run) DIAG 1 (red) in lower unit relay box lights
49 ECU warning malfunction (it is possible to run) DIAG 2 (amber) in lower unit relay box lights
Lower unit errors
16 Lower unit RAM check error
17 Failure in the lower A/D conversion
19 Lower unt ROM check error
28 Interrupted communication from STME to lower unit
29 Faulty communication from STM‐E to lower unit
36 Interrupted communication from upper to lower unit
37 Faulty communication from upper to lower unit
47 Faulty STM‐E
61 Failure in lower unit output power supply 1
62 Failure in lower unit output power supply 2
63 Failure in lower unit output power supply 3
64 Failure in lower unit output power supply 4
65 Failure in lower unit output power supply 5
66 Failure in lower unit output power supply 6
67 Failure in lower unit output power supply 7
68 Failure in lower unit output power supply 8
69 Failure in lower unit output power supply 9
70 Failure in lower unit output power supply 10
71 Failure in lower unit output power supply 11
72 Failure in lower unit output power supply 12
73 Failure in lower unit output power supply 13
74 Failure in lower unit output power supply 14
75 Failure in lower unit output power supply 15
76 Failure in lower unit output power supply 16
80 Monitored lower unit output data is unstable
90 Faulty RY1 output Monitored data ON while output data is OFF
91 Faulty RY2 output Monitored data ON while output data is OFF
92 Faulty RY3 output Monitored data ON while output data is OFF
93 Faulty RY4 output Monitored data ON while output data is OFF
94 Faulty RY5 output Monitored data ON while output data is OFF
95 Faulty RY6 output Monitored data ON while output data is OFF
96 Faulty RY7 output Monitored data ON while output data is OFF
97 Faulty RY8 output Monitored data ON while output data is OFF
98 Faulty RY1 output Monitored data OFF while output data is ON
99 Faulty RY2 output Monitored data OFF while output data is ON
9A Faulty RY3 output Monitored data OFF while output data is ON
9b Faulty RY4 output Monitored data OFF while output data is ON
9C Faulty RY5 output Monitored data OFF while output data is ON
9d Faulty RY6 output Monitored data OFF while output data is ON
9E Faulty RY7 output Monitored data OFF while output data is ON
9F Faulty RY8 output Monitored data OFF while output data is ON
A0 Faulty RY9 output Monitored data ON while output data is OFF
A1 Faulty RY10 output Monitored data ON while output data is OFF
A2 Faulty RY11 output Monitored data ON while output data is OFF
A3 Faulty RY12 output Monitored data ON while output data is OFF
A4 Faulty RY13 output Monitored data ON while output data is OFF
A5 Faulty RY14 output Monitored data ON while output data is OFF
A6 Faulty RY15 output Monitored data ON while output data is OFF
A7 Faulty RY16 output Monitored data ON while output data is OFF
A8 Faulty RY9 output Monitored data OFF while output data is ON
Перечень всех кодов неисправности - смотри в